✨ Get 20% OFF your first order. ✨

Your Shopping Bag

Your bag is empty

Subtotal $0.00
Shipping Calculated at checkout
Continue Shopping

Believe It Ge Sr489-p5-lo-a20-e Multilin Generator Management Relay Instant 75% Discount [yjLeHszE]

$57.99 $185.99 -69%

DescriptionThe SR489-P5-LO-A20-E from GE Multilin is a generator management relay designed for advanced protection functions, including overcurrent, offline conditions, and inadvertent energization. It features programmable curves, precise timing, an

Secure Shopping

100% Safe Guarantee

Free Shipping

On orders over $30

Money-Back

30-Day Guarantee

Description

The SR489-P5-LO-A20-E from GE Multilin is a generator management relay designed for advanced protection functions, including overcurrent, offline conditions, and inadvertent energization. It features programmable curves, precise timing, and flexible pickup levels.

Overcurrent Alarm

  • Pickup Level: 0.10–1.50 × FLA (0.01 steps, avg phase current)

  • Time Delay: 0.1–250.0 s (0.1 s steps)

  • Pickup Accuracy: Matches phase current inputs

  • Timing Accuracy: ±100 ms or ±0.5%

Offline Overcurrent

  • Pickup Level: 0.05–1.00 × CT (0.01 steps, any phase)

  • Time Delay: 3–99 cycles (1 cycle steps)

  • Pickup Accuracy: Matches phase current inputs

  • Timing Accuracy: ±50 ms @ 50/60 Hz

Inadvertent Energization

  • Arming Signal: Based on undervoltage or breaker status

  • Pickup Level: 0.05–3.00 × CT (0.01 steps, any phase)

  • Time Delay: No intentional delay

  • Pickup Accuracy: Matches phase current inputs

  • Timing Accuracy: ±50 ms @ 50/60 Hz

Phase Overcurrent

  • Voltage Restraint: Programmable fixed characteristic

  • Pickup Level: 0.15–20.00 × CT (0.01 steps, any phase)

  • Curve Shapes: ANSI, IEC, IAC, Flexcurve, Definite Time

  • Time Delay: 0.000–100.000 s (0.001 s steps)

  • Pickup Accuracy: Matches phase current inputs

  • Timing Accuracy: ±50 ms @ 50/60 Hz or ±0.5%

Negative Sequence Overcurrent

  • Pickup Level: 3–100% FLA (1% steps)

  • Curve Shape: I²t (k-defined), definite time alarm

  • Time Delay: 0.1–100.0 s (0.1 s steps)

  • Pickup Accuracy: Matches phase current inputs

  • Timing Accuracy: ±100 ms or ±0.5%

What Our Customers Say

December 30, 2025

Absolutely no complaints!

This is a very fine and a highly reliable tool.

- Jethro J..

December 30, 2025

Absolutely no complaints!

This is a really nice and a very, very useful gadget.

- Hywel I..

December 30, 2025

Absolutely no complaints!

My best purchase in the last entire whole month.

- Dyfed G..

Write a Review

You Might Also Like

Discover more great products from our collection.

ALLEN-BRADLEY 440T-KCSAC16MANA

ALLEN-BRADLEY 440T-KCSAC16MANA

(370)
$83.99 $268.99 -69%
Pochette Felicie Damier Ebene

Pochette Felicie Damier Ebene

(319)
$75.99 $243.99 -69%

Copyright 2025 © mappa-mercia.org

VISA
PayPal
Stripe
Mastercard
CASH ON DELIVERY