Seasonal Pick Ifm Iq2008 Inductive Sensor With Io-link In Multiple Colors [iBQKwRbn]
Product characteristics
| Electrical design |
PNP/NPN; (configurable) |
| Output function |
normally open / closed; (configurable) |
| Communication interface |
IO-Link |
| Housing |
rectangular |
| Dimensions [mm] |
20 x 8 x 32 |
Application
| System |
Drag chain suitability |
Electrical data
| Operating voltage [V] |
10...30 DC |
| Current consumption [mA] |
< 30 |
| Protection class |
III |
| Reverse polarity protection |
yes |
Outputs
| Electrical design |
PNP/NPN; (configurable) |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
100 |
| Switching frequency DC [Hz] |
300 |
| Short-circuit protection |
yes |
| Overload protection |
yes |
Monitoring range
| Switch point IO-Link [mm] |
1.4...7; (configurable) |
| Measuring range IO-Link [mm] |
0.75...7.5 |
Accuracy / deviations
| Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr] |
3...15 |
| Note on hysteresis |
|
| Linearity error IO-Link [%] |
± 2; (of the final value of the measuring range) |
| Repeatability IO-Link [%] |
± 1; (of the final value of the measuring range) |
| Temperature coefficient [%/K vom MEW] |
± 0,6; (-25...70 °C: ± 0,3) |
| Temperature drift |
± 10 %; (of the final value of the measuring range) |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel |
| SIO mode |
yes |
| Required master port class |
A |
| Min. process cycle time [ms] |
3.2 |
| IO-Link process data (cyclical) |
|
Function |
bit length |
|
process value |
16 |
|
device status |
4 |
|
binary switching information |
2 |
|
| IO-Link functions (acyclical) |
application specific tag; operating hours counter |
| Supported DeviceIDs |
|
Type of operation |
DeviceID |
|
default |
1106 |
|
| Note |
|
For further information please see the IODD PDF file at "Downloads" |
|
Operating conditions
| Ambient temperature [°C] |
-40...85 |
| Protection |
IP 65; IP 66; IP 67; IP 68 |
Tests / approvals
| EMC |
|
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
|
EN 61000-4-3 HF radiated |
10 V/m |
|
EN 61000-4-4 Burst |
2 kV |
|
EN 61000-4-6 HF conducted |
10 V |
|
EN 55011 |
class B |
|
| Vibration resistance |
|
EN 60068-2-6 Fc |
20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
|
| Shock resistance |
|
EN 60068-2-27 Ea |
100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
|
| Continuous shock resistance |
|
EN 60068-2-27 |
40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
|
| Fast temperature changes |
|
EN 60068-2-14 Na |
TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles |
|
| MTTF [years] |
787 |
| Embedded software included |
yes |
| UL approval |
|
Ta |
-25...70 °C |
|
Enclosure type |
Type 1 |
|
voltage supply |
Limited Voltage/Current |
|
UL approval number |
A015 |
|
File number UL |
E174191 |
|
Mechanical data
| Weight [g] |
79.2 |
| Housing |
rectangular |
| Mounting |
flush mountable |
| Dimensions [mm] |
20 x 8 x 32 |
| Material |
diecast zinc special coating; sensing face: PBT orange; LED window: TPU (urethane); potting: PUR |
| Drag chain suitability |
yes |
| Drag chain suitability |
|