Massive Discount Ifm Pi1805 Flush Pressure Sensor With Display Limited Time 55% Off [dX5EgFBa]
Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range -1...4 bar -14.5...58 psi -100...400 kPa Process connection threaded connection G 1 external thread sealing cone Attention
Secure Shopping
100% Safe Guarantee
Free Shipping
On orders over $30
Money-Back
30-Day Guarantee
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | |||
|---|---|---|---|---|
| Measuring range |
|
|||
| Process connection | threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
| System | gold-plated contacts | |||
|---|---|---|---|---|
| Application | flush mountable for the food and beverage industry | |||
| Media | viscous media and liquids with suspended particles; liquids and gases | |||
| Medium temperature [°C] | -25...150 | |||
| Min. bursting pressure |
|
|||
| Pressure rating |
|
|||
| Vacuum resistance [mbar] | -1000 | |||
| Type of pressure | relative pressure; vacuum | |||
| No dead space | yes | |||
| MAWP (for applications according to CRN) [bar] | 30 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
|---|---|
| Protection class | III |
| Reverse polarity protection | yes |
| Integrated watchdog | yes |
| Operating voltage [V] | 20...30 DC |
|---|---|
| Current consumption [mA] | 3.5...21.5 |
| Power-on delay time [s] | < 1 |
| Operating voltage [V] | 18...30 DC |
|---|---|
| Current consumption [mA] | 5...45; (430 bei max. Laststrom) |
| Power-on delay time [s] | < 0.5 |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analog signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20, invertible; (scalable) |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Max. load [Ω] | 300 |
|---|
| Max. voltage drop switching output DC [V] | 2 |
|---|---|
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 125 |
| Max. load [Ω] | (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V) |
| Measuring range |
|
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Set point SP |
|
||||||||||||
| Reset point rP |
|
||||||||||||
| Analog start point |
|
||||||||||||
| Analog end point |
|
||||||||||||
| Min. difference between SP and rP |
|
||||||||||||
| In steps of |
|
||||||||||||
| Factory setting |
|
| Measuring range |
|
|---|
| Switch point accuracy [% of the span] | < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1) |
|---|---|
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] | < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
What Our Customers Say
Absolutely no complaints!
Excellent craftsmanship and it performs flawlessly. Two thumbs up.
- Riley S..
Absolutely no complaints!
The quality shines through in every aspect of this product.
- Gia T..
Absolutely no complaints!
A phenomenal product. It performs at a professional level.
- Lila T..