High-quality 9144-c-p-156 Fluke Temperature Calibrator New Massive 30% Savings [MtaQdKwA]
Features: Each process version provides built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24V loop supply to power the transmitter Accuracy ranges from ±0.01°C to ±0.07°C dep
Secure Shopping
100% Safe Guarantee
Free Shipping
On orders over $30
Money-Back
30-Day Guarantee
Features:
- Each process version provides built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24V loop supply to power the transmitter
- Accuracy ranges from ±0.01°C to ±0.07°C depending on the measured temperature
- Accepts an ITS-90 reference PRT that contains individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably
- Second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermo-couples, or 4-20 mA transmitters
- With 24V loop power, you are able to power and measure the trans-mitter current while sourcing and measuring temperature thus allowing for the measurement of as-found and as-left data in one self-contained calibration tool
- Onboard non-volatile memory for documentation of up to 20 tests
- Each test can be given a unique alphanumeric ID and will record block temperature, reference temperature, UUT values, error, date, and time which can be viewed via the front panel or exported using Interface-it software (included)
- Stability indicator visually and audibly tells you the Field Metrology Well is stable to the selectable criteria
- Preprogrammed calibration routines are stored in memory for easy recall, and all inputs are easily accessible via the front panel of the instrument
Applications:
- Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration, Industrial Process
Specifications:
- Ref. Characterizations - 4-wire, ITS-90, CVD, IEC-751, Resistance
- Ref. Therm. Accuracy ±0.010°C @ -25°C, ±0.015°C @ 0°C, ±0.020°C @ 50°C, ±0.025°C @ 150°C, ±0.030°C @ 200°C, ±0.40°C @ 350°C, ±0.050°C @ 420°C, ±0.70°C @ 660°C
- Ref. Resistance Range - 0 to 400
- Ref. Resistance Accuracy - 0-25: ±0.002, 25-400: ±60 ppm
- RTD Characterizations - 4-wire RTD (2-, 3-wire RTD w/ jumpers only), PT-100 (385), (JIS), (3926), Ni-12, Resistance
- RTD Therm. Accuracy Ni-120: ±0.1°C @ 0°C; Pt-100 (385): ±0.02°C @ 0°C; Pt-100 (3926): ±0.02°C @ 0°C;Pt-100 (JIS): ±0.02°C @ 0°C
- RTD Resistance Range - 0 to 400
- RTD Resistance Accuracy - 0-25: ±0.002, 25-400: ±80 ppm
- T/C mV Range -10 to 75 mV
- Voltage Accuracy -10 to 50 mV: ±0.01 mV; 50 to 75 mV: ±250 ppm
- Cold Junction Comp. Accuracy - ±0.5°C (ambient of 13 to 33°C)
This unit has a built-in two channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20mA transmitters which includes the 24V loop supply to power the transmitter.
What Our Customers Say
Absolutely no complaints!
The quality is outstanding and the product is very easy to use.
- Camila V..
Absolutely no complaints!
The performance is smooth and the design is top-notch.
- Legacy Y..
Absolutely no complaints!
Superb quality and works like a charm. Very satisfied.
- Elijah S..